Home | About Us | Products | Download | Technical data | Contact Us
Location : ALIA >> Products >> Electromagnetic Flowmeter >>AMC3200DF Series
Electromagnetic Flowmeter
Ultrasonic Flowmeter
Variable Area Flowmeter
Vortex Flowmeter
Smart Differential Pressure Transmitter
Paperless Recorder
Communication
Multi-Function Calibrator
Smart Target Flowmeter
Other Instrumentation
Positive Displacement Flowmeter
Coriolis Mass Flowmeter
Relative Humidity Transmitter
Flow Computer
Ultrasonic Open Channel Flowmeter
Smart Temperature Transmitter
Ultrasonic Level Transmitter
Smart Transmitter for DP Flowmeter
Pressure Transmitter
Signal Converter
Water Meter
Thermal Mass Flowmeter
Swirl Flowmeter
AMC3200DF Series
The AMC3200DF Series...
AWF410 Series
AWF410 series featur...
AMC2200N Series
The ALIAMAG AMC2200N...
AST777 Series
The AST777 is a DTU ...
APF830 Series
The APF830 series is...
Tel:+1-213-533-4139
Fax:+1-213-223-2317
Email:alia@alia-inc.net
PDF Reader
Download
 
Products // Electromagnetic Flowmeter  
AMC3200DF Series

The AMC3200DF Series converter features in dual frequency excitation. The reduced noise and improved the signal to noise ratio makes it more idea for slurry measurement in various industries such as papermaking and chemistry. The unit features multiple display parameters including flow rate, flow total, diagnostics, programming and troubleshooting. It's equipped with bluetooth, HART and MODBUS communication functions.
FEATURES


 Dual Frequency Excitation Method  
 Three line LCD display Flow Rate / Totalizer  
 Accuracy of +/-0.4% value of reading  
 Bi-directional flow measurement, current and pulse output  
 Explosion Proof, Ex d (ia) llC T3-T6  
 Bluetooth / MODBUS / HART communication  
 Converter can be rotated at Four directions for easy installation

 
SPECIFICATION

Excitation: Keypad:
Dual Frequency Excitation 3 Internal keys for programming 
Display: and display control
3 Lines LCD with illumination Data Storage:
Line 1 Operation parameters and totalizer
8 Digit totalizer for forward flow figures are stored by EEPROM for more
8 Digit totalizer for reverse flow than 10 years
8 Digit totalizer for difference Low Flow Cutoff:
Line 2 0-9.9%
4 Digit flowrate / velocity / % / mA / Hz Damping:
Line 3 0-99 Seconds
Parameter / Query / Clr tot / Query LOG Density Setting:
Alarm, Guidance 0.001-9.999 g/cm3
Totalizer Unit Self Diagnosis:
t, kg, g, lb, Ston, Lton, m3, L, mL, Igal, gal, The following error message are
Mgal, bbl, ft3, a-ft   displayed if failure occurs
Time Unit -Abnormal sample
sec, min, hour, day -Pulse width
Measuring Range: -Overanged output
Min. 0-0.15 m/s -Internal error
Max. 0-15 m/s -Overflow
Accuracy: -Empty pipe
+/-0.4% of reading (Velocity>=1.0 m/s) Cable Entry:
+/-0.002 m/s (Velocity: 0.3...­1.0 m/s) Standard: M20  Option: 1/2" NPTF
Repeatability: Protection Class:
+/-0.2% of reading IP67, Explosion Proof, Ex d (ia) llC T3-T6
Current Output: Ambient Temperature:
4-20 mA (Isolated) -25~65 oC
Load Material:
Max. 500 Aluminum Alloy
Pulse Output: Power Supply:
Open collector 90-260 VAC, 50/60 Hz
Rating 24 VDC +/-10% (Option)
3-30 VDC, 50 mA Max.  Power Consumption:
Pulse Rate: 6-8 W (Dependent on sensor size)
1)Scale pulse (mL/Pusle, L/Pulse, Other) Weight:
2)Frequency: 0-5000 Hz 4.5 kg
Pulse Width: Mounting:
50% of band width Bracket on 2" pipe
Alarm: AMF Collocation Type:
High / Low with open collector output AMF900, AMF601, AMF500
Rating Sensor Size:
3-30 VDC, 50 mA Max.  DN50-DN450
Communication:
Bluetooth (Android) Standard
RS485 (MODBUS Protocol) Standard
HART signal (Compatible) Optional
 
 
All products
Dec. 2020 ALIA released n...
Dec. 2020 ALIA released n...
Oct. 2020 ALIA released n...
July 2020 ALIA released n...
May 2020 ALIA released ne...
Application
Calculator
Design
ARH950
ACF6000
APF810
AUF200 Series
AMF100 Series
AUT8500 Series
ACA60 Series
AHT530
ARC800
ATF80
AUF750 Series
ADP9000L Series
AMF900 Series
ADP9000 Series
       
WWW.ALIA-INC.COM Company  |  ALIA Product  |  Contact Us |  ZEROSPAN Copyright (C) 2007 ALIA-INC.COM All Rights Reserved.