Home | About Us | Products | Download | Technical data | Contact Us
Location : ALIA >> Products >> Vortex Flowmeter >>AVF7000 Series
Electromagnetic Flowmeter
Ultrasonic Flowmeter
Variable Area Flowmeter
Vortex Flowmeter
Smart Differential Pressure Transmitter
Paperless Recorder
Communication
Multi-Function Calibrator
Smart Target Flowmeter
Other Instrumentation
Positive Displacement Flowmeter
Coriolis Mass Flowmeter
Relative Humidity Transmitter
Flow Computer
Ultrasonic Open Channel Flowmeter
Smart Temperature Transmitter
Ultrasonic Level Transmitter
Smart Transmitter for DP Flowmeter
Pressure Transmitter
AMC2200 Series
The ALIAMAG AMC2200 ...
AUF770 Series
The AUF770 Series sa...
AVF250H Series
The AVF250H Series i...
ACA50 Series
The ACA50 Series sig...
APF860 Series
The APF860 Series is...
Tel:+1-213-533-4139
Fax:+1-213-223-2317
Email:alia@alia-inc.net
PDF Reader
Download
 
Products // Vortex Flowmeter  
AVF7000 Series

The AVF7000 Series is a Vortex Flowmeter based on Von Karman theory of vortices generated by a bluff body in the pipe. The number
of vortices are linearly proportional to the volumetric flow in the pipe.
The AVF7000 is versatile flowmeter widely used for Gases, Steam & Liquid applications. There are no moving parts and comes with either flange or wafer connection. Standard configuration has local indication for flowrate and total flow as well as 4-20 mA with HART signal and pulse output functions. The microprocessor design can filter out erroneous signals as well as interfence caused by pipe vibration.
FEATURES


 Simplified setup and self-diagnostic functions
 Auto. Temperature & Pressure compensation
 4-20mA with HART signal and pulse outputs, user selectable
 A very wide selection of sizes
 Wide temperature range up to 420 oC
 Non-volatile memory for setup and calibration

 
SPECIFICATION

Size: Local Display:
15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150 2 or 3 lines LCD
200, 250, 300, 350, 400, 450, 500 mm 6 Digit flowrate
Measuring Range: 8 Digit Totalizer
Steam -1.6~540,000 kg/hr Current Output:
Gas -3~46,000 m3/hr  4-20 mA (2 wire) with HART signal
Liquid -0.3~4950 m3/hr Load
Material: Rohm= (VDC-12) * 30
Stainless Steel 301 / 304 / 316 Pulse Output:
Accuracy Liquid: Scale Pulse 
+/-0.7% value of reading Load
Gas & Steam 1000-5000  
+/-1.0% value of reading Communication:
Unit: HART (Compatible)
Nm3/hr, Nm3/min, Nm3/s, m3/d, m3/hr, m3/min or RS485 (MODBUS Protocol)
m3/s, L/hr, L/min, L/s, t/d, t/hr, t/min, kg/d Data Storage:
kg/hr, kg/m, kg/s, g/hr, g/min, g/s Operation parameter and totalizer
Repeatability: figures are stored by EEPROM for more
+/-0.2% value of reading than 10 years
Process Connection: Housing Material:
Flange / Wafer Aluminum Alloy
Flange Type Cable Entry:
JIS 10K / JIS 20K / JIS 40K Standard: M20  Option: 1/2"NPTF
ANSI 150# / ANSI 300# / ANSI 600# Power Supply:
DIN PN10 / PN16 / PN25 / PN40 12-32 VDC
Wafer Type Ni-MH Battery (3 years working hours)
DN40-DN250 without Temp. / Pressure Sensor KeyPad:
Temperature: 3 Internal keys for programming
-40~280 oC (Standard) and display control
-40~420 oC (Optional) Option:
Ambient Temperature: Pressure Sensor
-20~60 oC Pressure compensation
Pressure: Signal Output
78 kgf/cm2 (Max.) 0-30 m VDC (20 uA Power Supply)
Protection Class: Temperature Sensor
IP65 Temperature compensation
Intrinsically Safe, Eex (ia) IIC T4 Signal Output
Explosion Proof, Ex d IIC T6 PT1000 (2 wires)

 
 
All products
July 2019 ALIA released n...
Apr. 2019 ALIA released n...
Apr. 2019 ALIA released n...
May 2018 ALIA released ne...
Mar 2018 ALIA released ne...
Application
Calculator
Design
ARH950
ACF6000
APF810
AUF200 Series
AMF100 Series
AUT8500 Series
ACA60 Series
AHT530
ARC800
ATF80
AUF750 Series
ADP9000L Series
AMF900 Series
ADP9000 Series
       
WWW.ALIA-INC.COM Company  |  ALIA Product  |  Contact Us |  ZEROSPAN Copyright (C) 2007 ALIA-INC.COM All Rights Reserved.