| Products
// Electromagnetic Flowmeter |
|
|
|
|
| AMF900 Series |
|
ALIAMAG AMF900 Series is a flange type Electromagnetic Flowmeter ideal for conductive liquids. It comes in sizes from 6 to 2000mm.
AMF900 is widely used for tap-water, waste water, food & beverage Pulp & Paper and many other industrial fluid.
AMF900 Series electromanetic flowmeter could be used in compact or separate model with AMC Series converter of electromagnetic Flowmeter.
|
|
|
|
| FEATURES |
|
Various liner and electrode can be selected to satisfy most industrial applications
Flow Velocity range:0-12 m/s, with precisely measure for low flow applications
It comes any flanges such as ,ANSI, DIN, JIS... etc
Excellent for high pressure application
Protection class: IP68 is available, and the sensor can sink into the water
FEP Liner is suit for vacuum tube
High accuracy of +/-0.4% value of reading (or +/-0.2% value of reading)
With Forward/Reverse flowrate measure function
|
| |
| SPECIFICATION |
|
| Size: |
Electrode & Grounding: |
| 6,10,15,20, 25,32,40,50,65,80,100,125 |
Stainless Steel 316L |
| 150,200,250,300,350,400,450,500,600 |
Hastelloy B |
| 700,800,900,1000,1200,1400,1600 |
Hastelloy C |
| 1800,2000 mm |
Titanium |
| Measuring Range: |
Tantalum |
| Velocity 0 - 0.25 m/s min. |
Platinum |
| 0 - 12 m/s max. |
Tungsten Carbide |
| Material: |
Cable Entry: |
| Measuring Tube |
2 X PG11 |
| Stainless Steel 304 |
Ambient Temperature: |
| Flange |
|
| Carbon Steel (standard) |
Process Connection: |
| Stainless Steel 304(Option) |
Flange |
| Stainless Steel 316,316L(Option) |
Flanges Type: |
| Coil Housing |
JIS 10K / JIS 20K / JIS 40K |
| Carbon Steel (standard) |
ANSI 150# / ANSI 300# / ANSI 600# |
| Stainless Steel 304(Option) |
DIN PN 10 / PN 16 / PN25 / PN 40 |
| Stainless Steel 316,316L(Option) |
Grounding Resistance: |
| Liner: |
Must be less then 10  |
| Polyurethane(25-600 mm) |
Accuracy: |
| Neoprene(50-2000 mm) |
+/-0.4% read-out values(Velocity>=0.5 m/s) |
| FEP(6-300 mm) |
+/-0.0025 m/s (Velocity < 0.5 m/s) |
| PTFE(25-800 mm) |
+/-0.2% read-out values |
| PFA(6-300 mm) |
(suit for AMC3100 Converter only) |
| Protection: |
Temperature: |
| IP 68 |
| -10 ~ +60 oC (Polyurethane,PU) | |
| IP 68 (Submersible) |
|
| Conductivity: |
|
| More than 5 uS/cm |
|
| Explosion Proof: |
Max. Pressure: |
| Exd(ib)ibqIIBT5 (with AMC3100 only) |
350 Kg/cm2 | |
|
|
|
 |
|
|