AMC2100E Series

AMC2100E series Converter With temperature/energy function can be used with AMF series flowmeter in both compact or separate versions.
FEATURES

 Four line LCD display Flowrate/Energy/Totalizer
 Accuracy of +/-0.4% of reading
 Bi-directional flow measurement, current and pulse output
 Large digital display,With temperature/energy function
 99 times records for power on/off
 MODBUS/HART communication
SPECIFICATION
Excitation: Keyboard:
Square wave 4 keys from external for programming 
Display: and display control.
4 lines LCD with back light Low Flow Cutoff:
Line 1 0 to 9.9 %
Date and Time Datalogger Function:
Line 2 99 times records for power on/off
6 digit flowrate Record Data:
7 digit energy value Date/Time when Power on/off
Fault code  99 years flow rate / energy /
Supply temperature Temperature / Total flow / Total energy
Line 3 One Record Data per Hour
9 digit totalizer for forward / reverse flow Damping:
9 digit totalizer for heat / cold  energy 0.1 to 99.9 Second
Fault code content Self Diagnosis:
Return temperature The following error message is 
Line 4 indicated during application
Differential temperature - Coil fail
Unit - Power fail
L/S , L/M , L/H , M3/S , M3/L , M3/H - Output overanged
KW , MW , KJ/H , MJ/H , GJ/H  - Internal error
Measuring Range: - Overflow
Min.  0 to 0.15 m/s - Empty pipe
Max. 0 to 15 m/s Cable Entry:
Accuracy: M16 * 1.5
+/-0.4% of reading (Velocity >= 0.5 m/s) Protection Class:
+/-0.002 m/s (Velocity < 0.5 m/s) IP 65
Repeatability: Ambient Temperature:
+/-0.1% of reading
-25 to +65 oC
Current Output: Material:
4-20 mA (Isolated) Aluminum Alloy
Load Temperature Input:
Max. 600 PT1000W, 2 wire 
Pulse output: Power Supply:
Open collector 90-260 VAC, 50/60 Hz
Rating 24 VDC +/- 10% (Option)
3 to 30 VDC, 20 mA Max.  Power Consumption:
Pulse Rate: 3-17 W (depending on the sensor size)
1)Scale pulse, (Pusle/M3, Pulse/L, Other) Weight:
2)Frequency, 0-5000 Hz 1.4 Kg
Communication: Mounting:
RS 485(MODBUS Protocol) Wall mounting
HART signal Bracket on 2" pipe
Data Storage:
Operation parameters and totalization 
figures are stored by EEPROM for more
than 10 years
 
 
All products
May 2010 ALIA newly add d...
Apr. 2010 ALIA released a...
Apr. 2010 ALIA released n...
Alia products with CE qua...
What we can do for the Vi...
Application
Calculator
Design
AUF750
AVF250
AUF610
AMF500 SERIES
AMF601
ADP9000L Series
AMC2100 Series
ADP9000 Series
APT8000 Series
ARC700 Series
AMC3100 Series
       
WWW.ALIA-INC.COM Company  |  ALIA Product  |  Forum  |  Contact Us Copyright (C) 2007 ALIA-INC.COM All Rights Reserved.