APT3000 Series |
|
APT3000 series pressure transmitter for general industrial application is the ideal solution for customers with demanding measuring
requirements. APT3000 very high quality product,which even the most adverse environmental conditions cannot affect.
The APT3000 offers continuous measuring ranges between 0-0.1 and 0-1000bar in all the major units. These measuring ranges can be combined
in the standard industry output signal. Application to machine builing, Hydraulics, peneumatics, pumps, chemical industry. |
|
FEATURES |
|
Improved performance, increased accuracy and greater stability
Non-linearing 0.2% of span (BFSL)
Measuring ranges from 0 - 0.1 bar ~ 0 - 1000 bar
Output signal: 4-20 mA (2 wires)
Zero point and span adjustable
Electrical connections:Angular connector
|
|
SPECIFICATION |
|
|
Process Fluid: |
Response Time: |
Liquid, Gas or Vapor |
<=1ms |
Application: |
Output Response Time: |
Absolute Pressure, Gauge Pressure, |
<=8ms |
Vacuum |
Current Output: |
Measuring Range: |
4 - 20 mA 2 wires |
0 - 0.1 bar ~ 0 - 1000 bar |
Load |
Accuracy: |
Rohm=(Vdc-15)*50 |
+/- 0.45% of span (Standard) |
Power Supply: |
+/- 0.20% of span (Option) |
11 - 36 VDC |
Non-Linearity: |
Material: |
<=0.2% of span (BFSL) |
Connection |
Non-Repeatability: |
Stainless steel SUS 304 |
<=0.05% of span |
Diaphragm |
Stability: |
Stainless steel SUS 316L |
<= +/-0.2% of URL for 1 year |
Body |
Working Temperature: |
Stainless steel SUS 304 |
-40 to +85 oC (Standard) |
Fill Fluid |
-40 to +125 oC (Option) |
Synthetic oil |
Compensation Temp.: |
Wetted O-ring (inside) |
-10 to +70 oC |
Viton |
Temp. Effect of zero: |
Electrical Connector: |
Ranges <= 0.25bar: |
PA66+30%FV |
<=0.4% FS/10K |
Electrical Connector: |
Ranges > 0.25bar: |
Ingress Protection |
<=0.2% FS/10K |
IP 65 |
Temp. Effect of span: |
Wire Cross-section |
<=0.2% FS/10K |
Max. 1.5mm2 |
Vibration Resistance: |
Cable Diameter |
20g (20~2000Hz) per IEC 60068-2-6 |
6-8mm |
Shock Resistance: |
Ambient Temperature: |
100g (10ms) |
-20 to +80 oC |
Adjustability: |
Humidity Limit: |
Zero Point |
5 to 95% Relative Humidity |
+/- 3% |
EMI/RFI Effect: |
Span |
Follow SAMA PMC 33.1 from 20 to 1000 |
+/- 15% |
MHz and for field strengths up to 30 V/m |
Process Connection: |
Dimensions: |
G1/4" (Standard) |
Standard |
1/2"NPT, 1/2" BSP, M20, 3/4"NPT |
48 mm ( W ) * 122 mm ( H ) * 34 mm ( D ) |
3/4"BSP ¡etc (Option) |
High Temperature |
Intrinsically Safe : |
48 mm ( W ) * 202 mm ( H ) * 34 mm ( D ) |
Ex ia IIC T6 (Standard) |
Weight: |
|
approx 0.2 Kg / 0.3Kg | |
|
|
|
 |
|
|
|
|